Baud Rate

Select the communication speed for data transmission with a connected device from the following.

2 400/4 800/9 600/19 200/38 400 bps Default: 9 600

Data Bit

The data bit will be displayed. It is impossible to change the value for this setting.

8(bit)

Parity

Select a method to check a transmission error at com- munication from the following.

None: No parity check

Even: Even parity

Odd: Odd parity

Default: None

Stop Bit

Select a stop bit from the following. 1 bit/2 bit

Default: 1 (bit)

Retry Timing

Select a retransmission interval for when data reception is not confirmed from the following.

Off/100 ms/200 ms/400 ms/1 000 ms Default: Off

Alarm Data

Select a method to inform the connected controller of an event occurrence from the following.

Off: Does not function.

0s: Informs the controller every time an event is detect- ed.

1s/5s: Informs the controller when a specified time has passed after detecting an event.

Default: 1 s

Camera Number Setup

It is possible to assign a number to each camera chan- nel to operate cameras using the controller compatible with PS·Data.

Do the following to assign numbers to the camera chan- nels.

(1)Move the cursor onto "Set" next to "Channel No." and press the [SET] button.

The "Channel No." menu will be displayed.

 

 

Camera Number Setup

 

 

 

Port

Cam

Port

Cam

 

 

 

 

 

 

 

 

 

 

 

1

 

001

 

2

 

002

 

 

 

 

 

 

 

 

 

 

 

3

 

003

 

4

 

004

 

 

 

 

 

 

 

 

 

 

 

5

 

005

 

6

 

006

 

 

 

 

 

 

 

 

 

 

 

7

 

007

 

8

 

008

 

 

 

 

 

 

 

 

 

 

 

9

 

009

 

10

 

010

 

 

 

 

 

 

 

 

 

 

 

11

 

011

 

12

 

012

 

 

 

 

 

 

 

 

 

 

 

13

 

013

 

14

 

014

 

 

 

 

 

 

 

 

 

 

 

15

 

015

 

16

 

016

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

Cancel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2)Assign a camera number (to be operated using the controller) for each camera port using the camera selection buttons.

(3)After completing the camera number assignment, move the cursor onto [OK] and press the [SET] but- ton.

65