Panasonic WJ-RT416V manual Maintenance functions Maintenance, Check the alarm log Alarm Log

Models: WJ-RT416 WJ-RT416V

1 80
Download 80 pages 18.29 Kb
Page 68
Image 68

Maintenance functions [Maintenance]

Configuration of the settings relating to the HDDs, the system information check, log check, and initialization of the settings are available.

Maintenance

Alarm Log

Error Log

System Information

Current Recording Setting

Disk Management

Online User Information

Factory Default

Reboot System

Advanced Information

q

w

e

r

t

y

u

i

o

q Check the alarm log [Alarm Log]

The alarm logs (time and date of the event occurrence and event) will be displayed in the list form. Refer to page 27 for further information about the events.

Up to 9 990 alarm logs can be kept and the older logs will be overwritten by the newer logs. The following is the descriptions of the alarm log.

Port=n Terminal input: Terminal input

Cam=n VMD: VMD alarm

Cam=n Command alarm reception: Command alarm

* n: Alarm No.

w Check the Error Log [Error Log]

The error logs (time and date of the error occurrence and event) will be displayed in the list form. Up to 500 error logs can be kept and the older logs will be overwritten by the newer logs.

The following is the descriptions of the error log. Thermal Error

Fan=a Error HDD Full

Full Records (Reached the maximum number of files possible to keep.) HDD=n Access Error

HDD=n SMART Warning Cam=m Loss Signal Cam=m Get Signal

Password Error (Incorrect password has been entered three times in a row.) No Disk

HDD=n Write Error

*a: Fan number (1 - 5)

*n: HDD number (1 - 6)

*m: Camera No. (1 - 16)

68