Configure the settings relating to communications with other devices [Communication Setup]

It is necessary to conform the setting such as the communication protocol and the line speed when connecting an external device such as a system controller to the DATA port or the RS485 port.

It is also necessary to configure the network settings such as the IP address and the gateway address to operate the recorder using a PC via a network.

The following is the required setting to communicate with external devices.

Communication Setup

Network Setup

RS485 Setup

PS.Data Setup

q

w

e

q Configure the network settings [Network Setup]

To operate the recorder using a PC via a network, configure the basic network settings.

Network Setup

DHCP

IP Address

Subnet Mask

Gateway

Line Speed

Advanced Setup

Off

192.168.000.250

255.255.255.000

192.168.000.001

Auto

Set

OK

Cancel

DHCP

Select "On" or "Off" to determine whether or not to use the DHCP server.

Select "On" when obtaining values for "IP Address", "Subnet Mask" and "Gateway" from the DHCP server.

Select "Off" when entering values for "IP Address", "Subnet Mask" and "Gateway" manually.

On: Use the DHCP server

Off: Not use the DHCP server

Default: off

IP Address

Enter an IP address. For this recorder, enter 4 units from the decimal numbers (0-255).

Default: 192.168.0.250

Subnet Mask

Enter a subnet mask according to the network configura- tion.

Default: 255.255.255.000

Gateway

Enter a gateway address according to the network configu- ration.

Default: 192.168.0.1

Line Speed

The following is available for the line speed. Auto: Line speed will be applied automatically. 100M-Half:100 Mbps half duplex 10M-Half:10 Mbps half duplex

100M-Full:100 Mbps full duplex

10M-Full:10 Mbps full duplex

Default: Auto

63

Page 63
Image 63
Panasonic WJ-RT416V manual Configure the network settings Network Setup