ALARM IN/CONTROL terminal

!3 q

 

 

ALARM IN/CONTOROL

 

 

 

 

@5

!4

 

 

 

 

 

 

Pin No.

Signal

Operation

 

Remark

 

 

 

 

q

Alarm input CH1

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

w

Alarm input CH2

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

e

Alarm input CH3

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

r

Alarm input CH4

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

t

Alarm input CH5

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

y

Alarm input CH6

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

u

Alarm input CH7

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

i

Alarm input CH8

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

o

Alarm input CH9

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

!0

Alarm input CH10

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

!1

Alarm input CH11

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

!2

Alarm input CH12

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

!3

Alarm input CH13

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

!4

Alarm input CH14

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

!5

Alarm input CH15

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

!6

Alarm input CH16

An event action will be taken according

Non-voltage make contact input, pulse

to the setting.

 

width: 100 ms or more

 

 

 

 

 

 

 

 

 

The clock of the recorder will be set to

Non-voltage make contact input, pulse

!7

Time adjust input

00 (min) by signal input. (Time correc-

width: 100 ms or more

 

 

tion range: ±15 minutes)

 

 

 

 

 

 

 

 

Signal output upon an error detection

 

 

 

(Thermal error (47 °C {117 °F} or high-

Open collector output, 100 mA or less,

!8

Error output

er), fan error, video loss, password

24 V DC max.

 

 

entry failure (3 times straight incorrect

 

 

 

 

 

password entry), no HDD detection)

 

 

 

 

 

!9

HDD error output

Signal output upon a HDD error detec-

Open collector output, 100 mA or less,

tion

 

24 V DC max.

 

 

 

 

 

 

 

@0- @4 (Signal GND)

 

 

 

 

 

 

 

 

@5

(N.C.)

Not available

 

 

 

 

 

 

 

50

Page 50
Image 50
Panasonic WJ-RT416V manual Alarm IN/CONTROL terminal