Advanced Setup

The following window will be displayed when the [SET] but- ton is pressed after moving the cursor onto "Set".

Network Setup (Advanced)

DNS

Off

 

 

 

 

 

 

 

 

 

 

 

 

IP Address (Primary)

---.---

 

.

---.---

 

 

 

 

 

 

 

 

IP Address (Secondary)

---.---

 

.

---.---

 

 

 

 

 

 

 

Server Port

02000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

Cancel

DNS

Select "Manual" or "Auto" to enable IP address searching by the host name using the DNS.

Select "Off" when not using the DNS.

Selecting "Auto" is available only when "On" is selected for "DHCP" (using the DHCP server).

When "Manual" is selected for the DNS, enter the DNS serv- er addresses in "IP Address (Primary)" and "IP Address (Secondary)".

Enter 4 units from the decimal numbers (0-255) according to the network configuration.

Default: Off

Server Port

Set the server port number of the recorder (required to use the monitoring software).

1 - 65535 Default: 2000

w Configure the RS485 settings [RS485 Setup]

Configure the RS485 settings.

RS485 Setup

Baud Rate

 

19200

 

 

 

 

 

Data Bit

8

 

Parity

 

 

None

Stop Bit

1

 

 

 

 

 

 

OK

 

 

Cancel

Baud Rate

Select a line speed for data communication with the con- nected device from the following.

2 400/4 800/9 600/19 200/38 400 (bps) Default: 19 200 (bps)

Data Bit

The data bit will be displayed. It is impossible to change the value.

Parity

A method of checking for errors in communication function- ing will be displayed. It is impossible to change the value.

Stop Bit

The stop bit type will be displayed. It is impossible to change the value.

e Configure the PS·Data settings [PS.Data

Setup]

Configure the PS·Data settings.

 

PS.Data Setup

 

 

 

 

 

 

 

 

 

 

 

Unit Address(System)

 

001

 

 

 

 

 

 

 

 

 

Unit Address(Controller)

002

 

 

 

 

 

 

 

 

 

 

Baud Rate

 

9600

 

Data Bit

 

8

 

 

 

 

 

 

 

 

 

 

Parity

 

None

 

 

 

 

 

 

 

 

 

Stop Bit

 

1

 

 

 

 

 

 

 

 

 

 

Retry Timing

 

Off

 

 

 

 

 

 

 

 

 

Alarm Data

 

1s

 

 

 

 

 

 

 

 

 

Camera Number Setup

 

Set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

Cancel

 

 

 

 

 

 

 

 

 

 

Unit Address (System)

A unit address (Sys) is a unique number assigning to PS·Data devices. The addresses must be unique to identify system devices when connecting multiple devices compatible with PS·Data.

Numbers, "001"-"099", are to be assigned as the unit addresses to the system devices.

Default: 001

Unit Address (Controller)

A unit address (Ctrl) is a unit address assigning to con- trol PS·Data devices. Numbers, "002"-"099", are to be assigned as the unit addresses to the system controller. Default: 002

64

Page 64