Diagnostics and Troubleshooting

Table 5-4. Minor Alarms (2 of 2)

Failure Type

Action

 

 

Error Rate

H If the Error Rate Threshold is < 10-4, then this alarm is a warning

Threshold

that the loop has degraded. The actual bit rate should still be above

(A trap

10 -7. This condition may be temporary due to high temperature or

message sent if

humidity/rain. It may be permanent due to high noise from

the Block Error

additional digital circuits installed in the same cable bundle.

Rate averaged

H If the Error Rate Threshold is >10-4, then this alarm is a warning

over a period of

time exceeds

that the loop has degraded. The actual bit rate may be below 10-7.

This condition may be temporary or permanent. However, if it

the selected

persists, the loop may have to be reengineered for better

value.)

performance by performing one of the following:

 

 

– Remove bridge taps

 

– Change cable gauge on a cable section

 

– Run new cable

 

– Remove other noise-generating digital circuits from the cable

 

bundle

 

 

Link Down

H If the threshold is set low (1–4), and the link is currently down, then

Threshold

there may be a loop or RTU problem. Check both.

(A trap

– Verify that the RTU is powered up, is connected to the loop, and

message sent if

has passed its Selftest.

the number of

– Check the loop for continuity

DSL link down

 

events in

H If the threshold is set low (1–4), and the link is currently up, then an

15 minutes

event had occurred to temporarily knock out the connection. Log

exceeds the

the event and continue normal operation.

selected value.)

H If the threshold is set high (> 4), and the link is currently down, then

 

 

check the Margin statistics over the past hour and day. If the

 

numbers are low, there may be a situation where the DSL modems

 

cannot train. This condition may be temporary or permanent.

 

However, if it persists, the loop may have to be reengineered for

 

better performance by performing one of the following:

 

– Remove bridge taps

 

– Change cable gauge on a cable section

 

– Run new cable

 

– Remove other noise-generating digital circuits from the cable

 

bundle

 

H If the threshold is set high (> 4) and the link is currently up, then

 

there may be a loose connection in the loop plant, or the loop is

 

barely usable. Check the Margin. If the Margin is normal, there may

 

be a loose connection. If the Margin is low, try reducing the speed

 

of the DSL port.

 

 

5-8

April 2000

8000-A2-GB20-50