S a m p l e V e r i f i e r C o n f i g u r a t i o n P a c k e t
{V,1,A,T,”BEAMON”¦
D,"~LV02~HL0~HO2~LR1~Lp0~Lt0~LQ0~PR0210~LC01~LA15~LD05~PB
802037100~PB816005100~PB806025100"¦}
You can modify the verifier configuration packet or create your own using the SV Series Operator’s Guide. However, you need to the follow the MPCLII conventions and syntax outlined below.
The printer automatically sets the following verifier commands:
~LS (minimum number of good scans per bar codes), ~LZ (Exact number of bar codes per label), ~SD/~SE (disable or enable the scan beam), and ~LE/~LI (disable or enable symbology). If you specify any values for these parameters, the printer overrides your values. For more information, refer to the SV Series Operator’s Guide included with the verifier.
Note: You can store up to 50 different verifier configuration packets in the printer’s memory.
D e f i n i n g t h e V e r i f i e r C o n f i g u r a t i o n P a c k e t
Read this section if you want to create the verifier configuration packet without using the VCT.
Syntax {V,format#,action,device,”name”¦D,”vfr_comds”¦}V1 | . V | Verifier Configuration. | |
V2 | . format# | Number from | |
|
| corresponds to this particular verifier configuration | |
|
| packet. However, you can assign a verifier | |
|
| configuration packet to any format even if the format | |
|
| number is not changed. See “Defining the Verifier | |
|
| Field,” for more information. | |
|
| You can specify up to 50 different verifier | |
|
| configuration packets. | |
V3 | . action | Enter A to add a verifier configuration. | |
V4 | . device | Storage device. Options: | |
|
| F | Flash. Stores the verifier configuration in |
|
|
| the printer. Packets stored in flash memory |
|
|
| are saved with the power is turned off. |
|
| T | Temporary. Passes the packet through the |
|
|
| printer and stores the packet in the verifier. |
Packets stored in temporary memory are lost when the power is turned off.