Switch
Fibre Channel Protocols: | |
| |
| |
| |
| |
| |
| |
| |
Fibre Channel Classes of Service: | Class 3, Class 2 |
Modes of Operation: | Connectionless only: Class 2 and/or Class 3 |
| Mixed Mode: |
Fabric Port Types: | F_Ports, FL_Ports, SL_Ports, TL_Ports, |
| T_Ports. |
| 100% of all Switch ports can be any of the |
| above ports. |
Number of Fibre Channel Ports: | 16 Ports per chassis; Populated by 2 to 16 |
| GBICs in one GBIC increments. |
Scalability: | Up to 192 fabric ports in a |
| topology. |
| |
Chassis Hops: | Mesh topology - 1 or 2 chassis latencies |
| Cascade topology - 1 to 4 chassis latencies |
| depending on the number of chassis |
| cascaded. |
| Multistage topology - 1 or 3 chassis laten- |
| cies. |
Maximum User Ports: | A |
| N_Ports and NL_Ports. |
| A |
| up to ~12,000 N_Ports and NL_Ports. |
Buffer Credits | Each port has eight buffer credits. This |
| allows a cable length up to 13 km at 1 Gbps |
| without performance degradation. Cable |
| length is also dependant on the type of GBIC |
| used. |
| ||
| Installer’s/User’s Manual |