Power Supply

Power Supply

DANGER:

Do not attempt to open the covers of the power supply. Power supplies are not serviceable and must be replaced as a unit.

GEFAHR:

Versuchen Sie auf keinen Fall, die Abdeckung des Netzteils zu entfernen. Die Netzteile sind nicht wartbar. Sie müssen als ganze Einheit ersetzt werden.

DANGER:

L’alimentation électrique ne se répare pas. En cas de panne, la remplacer au complet. Ne pas essayer d’en ouvrir le boîtier.

Removal

If the Switch contains two Power Supplies, either supply is “Hot-Pluggable”. That is, one supply can be removed while the Switch is powered-up and operating as long as the other supply is operating properly.

1.Refer to Figure 4-6. Use a large flat-blade screwdriver to turn each of the two Locking-Screws 1/4 turn counterclockwise.

2.Pull the Power Supply straight out of the back of the Switch Chassis. If the Switch contained two power supplies and will now be operating with only one until the second supply is replaced, install the Cover Plate over the bay. A Cover Plate came with the Switch.

Chassis Back

Power Supply

Locking Screws

Fan

Figure 4-6 Power Supply Removal

4-6Removal/Replacement Procedures

 

SANbox-16HA Fibre Channel Switch

59005-03 Rev. A

Installer’s/User’s Manual

Page 82
Image 82
Q-Logic 16HA user manual Power Supply