AC Input Power Connectors and Fuses
Traffic LED (Yellow)
Each port has its own Port Activity LED. The Port Activity LED for a particular port is ON when Class 2, or 3 frames are entering or leaving the port. The Switch turns the LED ON for 50 msec. for each frame, so you should be able to see it for one frame. This LED will not light for frames following an arbitrated loop in bypass mode.
AC Input Power Connectors and Fuses
Refer to Figure 1-5. The chassis contains two Input Power Assemblies, one for each power supply. The left assembly serves the left Power Supply. The right assembly serves the right Power Supply. Each assembly contains a connector for a standard 3-wire computer-type AC power cable (supplied with the Switch). The power cable connects between an AC Input Power Connector and an AC outlet. For purposes of redundancy, the AC outlets should be on separate circuits. Refer to Appendix A Reference Information for the AC Power Requirements. See also Section 2 Installation for installation procedures.
An Input Fuse Holder is incorporated into each AC Input Power Connector assembly. they each hold two input fuses. Refer to Section 3 Diagnostics/Trouble- shooting and to Section 4 Removal/Replacement Procedures. Refer also to Appendix A Reference Information for fuse size.
Switch Management Connector
Refer to Figure 1-5. The Switch Management Connector is a 10/100BASE-T Ethernet interface that provides a connection to a management station. Refer to the Switch Management manual for information about how to connect the manage- ment station and manage the Switch.
1-22General Description | | SANbox-16HA Fibre Channel Switch |
59005-03 Rev. A | Installer’s/User’s Manual |