SANbox-16HA Fibre Channel Switch Specifications

 

 

Switch Mechanical

 

Chassis Dimensions:

Refer to Figure A-1 and Figure A-2.

Enclosure Types:

The chassis is shipped with four rubber feet

 

on the bottom for secure stacking. Cabinet

 

Mounting Brackets are also shipped with the

 

chassis. You may mount these brackets on the

 

front or back of the chassis for mounting in a

 

Standard 19-inch EIA rack with either the

 

chassis back or front facing the front of the

 

equipment rack.

Chassis Support:

The chassis MUST be supported by a shelf

 

or rails when rack-mounted

Chassis Weight:

32 lbs maximum configuration

Switch Electrical

 

Power source loading:

1.7 Amps maximum at 90 to 137 Vac

 

0.9 Amps maximum at 180 to 265 Vac

Each Power Supply:

140 Watts

Operating voltage:

90 to 137 Vac; 47 to 63 Hz

 

180 to 265 Vac; 47 to 63 Hz

Input Fuse Type:

There is one input fuse. The

 

fuse is a 4 Amp Slow-Blow, 250V

 

Littelfuse P/N 218004 or equivalent

Switch Environmental

 

Operational Temperature:

5 to 40°C

Operating Humidity:

15 to 80%, non-condensing

Operating Altitude:

0 to 3048m (0 to 10,000 feet)

Operating Vibration:

During/after (in any axis) of magnitude:

 

5-500 Hz, random,

 

0.21 G rms, 10 minutes

Operating Shock:

During/after (in any axis) of magnitude:

 

4g, 11 ms, 20 repetitions

Air flow:

Cooling air flows from the front to the back.

Heat output:

600 BTU/hr fully populated

Non-Operational Temperature:

..........-40 to +70°C

Non-Operating Humidity:

5 to 90%, non-condensing

SANbox-16HA Fibre Channel Switch

 

Reference Information A-5

Installer’s/User’s Manual

59005-03 Rev. A