SANbox-16HA Fibre Channel Switch Specifications

Switch Maintainability

Maintenance Strategy:

FRU-based:

 

GBIC Modules

 

Power supplies/fans

 

AC input fuses

 

Does not require enclosure opening for any

 

reason, including:

 

GBIC insertion to populate/activate

 

new ports

 

GBIC replacement

 

Redundant power supply replacement

 

Does not require system interruption for:

 

GBIC insertion to populate/activate

 

new ports

 

GBIC replacement

 

Redundant power supply replacement

Backup Components:

Hot-swappable spare power supply and

 

integral cooling fan. Redundant Power

 

Cables and Input Fuses)

Diagnostics:

Power-On-Self-Test (POST) tests all

 

functionality except media modules.

 

Field selectable Continuous Test tests all

 

functionality including media modules.

Fabric Management

 

Fabric Management:

Simple Name Server, Alias Server, SNMP,

 

the SANsurfer Web-based Java application,

 

and Telnet

User Interface:

LED indicators

Maintenance Interface:

Ethernet 10/100 BASE-TEthernet

Connector:

RJ-45

A-4Reference Information

 

SANbox-16HA Fibre Channel Switch

59005-03 Rev. A

Installer’s/User’s Manual

Page 108
Image 108
Q-Logic 16HA user manual Switch Maintainability, Fabric Management