6 – Removal/Replacement Power Supply Removal and Replacement

1.Confirm that the Heartbeat LED is showing the normal 1 blink per second. This allows the switch to correctly report power supply status.

2.Confirm that the new power supply is compatible with the switch air flow direction. The part number label on the power supply indicates the air flow direction as shown in Figure 6-2.

3.With the AC receptacle on the right, slide the power supply into the bay until it is firmly seated. Secure the knurled fasteners by hand.

4.Plug the power cord into the AC receptacle and confirm that the air flow is correct.

Air Flow

AC

Label

Receptacle

 

Figure 6-2. Power Supply Installation