A
5 – Diagnostics/Troubleshooting
5.2
Power-On Self Test Diagnostics
The switch performs a series of tests as part of its
Checksum tests on the boot firmware in PROM and the switch firmware in flash memory
Internal data loopback test on all ports
Access and integrity test on the ASIC
During the POST, the switch logs any errors encountered. Some POST errors are critical, others are not. The switch uses the Heartbeat LED and the
If there are no errors, the Heartbeat LED blinks at a steady rate of once per second. If a critical error occurs, the Heartbeat LED will show an error blink pattern and the System Fault LED will illuminate. If there are
5.2.1
Heartbeat LED Blink Patterns
The Heartbeat LED indicates the operational status of the switch. When the POST completes with no errors, the Heartbeat LED blinks at steady rate of once per second. When the switch is in maintenance mode, the Heartbeat LED illuminates continuously. Refer to “Recovering a Switch Using Maintenance Mode” on page
The Heartbeat LED shows an error blink pattern for the following conditions:
1 blink - Normal operation
2 blinks - Internal Firmware Failure Blink Pattern
3 blinks - Fatal POST Error Blink Pattern
4 blinks - Configuration File System Error Blink Pattern
5 blinks - Over Temperature Blink Pattern