5 – Diagnostics/Troubleshooting Chassis Diagnostics

S

5.1.1

Input Power LED Is Extinguished

The Input Power LED illuminates to indicate that the switch logic circuitry is receiving proper voltages. If the Input Power LED is extinguished, do the following:

1.Inspect the power cords and connectors. Is the cord unplugged? Is the cord or connector damaged?

„Yes - Make necessary corrections or repairs. If the condition remains, continue.

„No - Continue.

2.Inspect the AC power source. Is the power source delivering the proper voltage?

„Yes - Continue.

„No - Make necessary repairs.

‰For a model 5200/5600 switch, if the condition remains, contact your authorized maintenance provider.

‰For a model 5202/5602 switch, if the condition remains, continue.

3.Inspect the power supplies. Are the power supplies fully seated in their bays?

„Yes - Continue. Replace the power supplies.

„No - Reinstall the power supplies. If the condition remains, replace the power supplies.

5.1.2

System Fault LED Is Illuminated

The System Fault LED illuminates to indicate that a fault exists in the switch firmware or hardware. If the System Fault LED illuminates, do the following:

„Check the Heartbeat LED for an error blink pattern and take the necessary actions. Refer to “Heartbeat LED Blink Patterns” on page 5-3.

„For a model 5202/5602 switch, check the power supply LEDs and take the necessary actions. Refer to “Power Supply Diagnostics” on page 5-12.

5-2

59096-04 A

Page 94
Image 94
Q-Logic 5000 manual Input Power LED Is Extinguished, System Fault LED Is Illuminated