A

4 – Installation Installing Firmware

NOTE: You can load and activate version 6.7 firmware on an operating switch without disrupting data traffic or having to re-initialize attached devices. If you attempt to perform a non-disruptive activation without satisfying the following conditions, the activation will fail. If the non-disruptive activation fails, you will usually be prompted to try again later. Otherwise, the switch will perform a disruptive activation.

„The current firmware version permits the installation and non-disruptive activation of 6.7 firmware. Refer to the 6.7 Firmware Release Notes for previous compatible firmware versions.

„No changes are being made to switches in the fabric including powering up, powering down, disconnecting or connecting ISLs, changing switch configurations, or installing firmware.

„No port in the fabric is in the diagnostic state.

„No Zoning Edit sessions are open in the fabric.

„No changes are being made to attached devices including powering up, powering down, disconnecting, connecting, and HBA configuration changes.

„Install firmware on one switch at a time in the fabric. If you are installing firmware on one switch, wait 120 seconds after the activation is complete before installing firmware on a second switch.

„For a fabric in which all switches are running 6.7 firmware, no more than two Enterprise Fabric Suite 2007 sessions can be open.

„For a fabric in which one or more switches are running firmware prior to version 6.7, only one Enterprise Fabric Suite 2007 session can be open.

Ports that are stable when the non-disruptive activation begins, then change states, will be reset. When the non-disruptive activation is complete, Enterprise Fabric Suite 2007 sessions reconnect automatically. However, Telnet sessions must be restarted manually.

59096-04 A

4-17

Page 87
Image 87
Q-Logic 5000 manual Installation Installing Firmware