2 – General Description Chassis Controls and LEDs

2.1.1.2

Placing the Switch in Maintenance Mode

To place the switch in maintenance mode, do the following:

1.Isolate the switch from the fabric.

2.Press and hold the Maintenance button with a pointed tool for a few seconds until the Heartbeat LED alone is illuminated. Continue holding the maintenance button until the Heartbeat LED extinguishes, then release the button. The Heartbeat LED illuminates continuously while the switch is in maintenance mode.

To exit maintenance mode and return to normal operation, momentarily press and release the Maintenance button to reset the switch.

2.1.2

Chassis LEDs

The chassis LEDs provide status information about switch operation. Figure 2-3identifies the chassis LEDS on a model 5200/5600 switch. The model 5202/5602 switch LED arrangement is the same. Refer to “Port LEDs” on page 2-6for information about port LEDs.

Input Power LED

 

(Green)

 

L 0 A L 1 A L 2 A L 3 A

L 4 A L 5 A L

Heartbeat LED

 

(Green)

 

System Fault LED

 

(Amber)

 

Figure 2-3. Chassis LEDs