A

5 – Diagnostics/Troubleshooting Power-On Self Test Diagnostics

4.Compare the RA_TOV and ED_TOV timeout values for all switches in the fabric using the Show Config Switch command. Is each timeout value the same on every switch?

„Yes - Continue.

„No - Correct the timeout values on the offending switches using the Set Config Switch CLI. Reset the port. If the condition remains, continue.

5.Display the active zone set on each switch using the Zoning Active command. Compare the zone membership between the two active zone sets. Are they the same?

„Yes - Contact your authorized maintenance provider.

„No - Deactivate one of the active zone sets or edit the conflicting zones so that their membership is the same. Reset the port. If the condition remains, contact your authorized maintenance provider.

NOTE: This can be caused by merging two fabrics whose active zone sets have two zones with the same name, but different membership.

5.2.2.2

Excessive Port Errors

The switch can monitor a set of port errors and generates alarms based on user-defined sample windows and thresholds. These port errors include the following:

„CRC errors

„Decode errors

„ISL connection count

„Device login errors

„Device logout errors

„Loss-of-signal errors

Port threshold alarm monitoring is disabled by default. Refer to the SANbox 5000 Series Fibre Channel Switch Command Line Interface Guide for information about managing port threshold alarms.

59096-04 A

5-9

Page 101
Image 101
Q-Logic 5000 manual Excessive Port Errors