Adjusting the Fusing Temperature Manually

1Press the Copy Media key to turn on the “Vellum” or “Film” indicator that you want.

2Hold down the Copy Media key for at least 3 seconds.

The “Lighter Copy” display will show the current fusing temperature. The unlit indicator shows the current temperature.

3Press the Lighter key to decrease the tempera- ture, and press the Darker key to increase the temperature.

The number of temperature levels available

depends on the paper type:

Plain paper

:

1234567

Vellum

:

1234

Film

:

1234

Energy

 

Set

Clear Modes/

 

Energy Saver

Saver

 

Original

 

 

Set

RF

 

 

Paper

Select

Program

 

 

Wait

 

 

 

Vellum

Lighter Copy

 

 

 

 

Film

 

 

 

Copy Media Lighter

Darker

Clear/Stop

Emergency Stop

4After you have finished the setting, press the Copy Media key.

5 Choose any copy settings you require, then start copying.

Notes

The new fusing temperature for the selected paper type is cleared when you press the Clear Modes key or turn off the main switch.