Operating Instructions Administrator Reference
110
NetBEUI
AClick the [General] tab, and then type the comment into the [Comment] box.
In the [Comment] box, type any comment on printers within 31 characters.
BClick the [NetBEUI] tab.
CType the computer name into the [Computer Name] box.
In the [Computer Name] box, type the name that helps you to identify printers using the Net-
BEUI protocol. The factory default name consists of "RNP" and the last 3 bytes of the MAC
address on the Network Interface Board. For example, when the MAC add ress is
00:00:74:62:7D:D5, the factory default name is "RNP627DD5". A maximum of 13 charac-
ters consisting of uppercase English le tters, numeric, or symbols (except "*+,/: ;<=>?[\]|. and
space) can be used. No name is permitted if the prefix is "RNP". You must avoid the dupli-
cation of the same name on a network.
F
FF
FClick [OK].
The NIB Setup Tool exits, and the setting is transmitted to the printer.
G
GG
GExit SmartNetMonitor for Admin.