USER'S MANUAL

2.PRE ALARM TIME LIMIT

-PRE ALARM recording is a feature that recognizes what kind of conditions were present immediately before motion was detected. PRE ALARM TIME LIMIT can be set to record 5 seconds of video right before motion detection or an ALARM occurrence. The System memory always saves up to 5 seconds of video data. When motion is detected or an ALARM occurs, ALARM recording starts and PRE-ALARM data is simultaneously recorded from the System memory to HDD up to the time length set in PRE ALARM TIME LIMIT.

[0SEC, 5SEC]

-Use , , , , key to make changes.

3.POST ALARM TIME LIMIT

-Recording is performed up to the time set in MAIN ALARM TIME. Then data is further recorded up to the time set in POST ALARM TIME LIMIT.

[10SEC ,20SEC ,30SEC ,1MIN ,2MIN ,3MIN ,4MIN ,5MIN]

-Use , , , , key to make changes.

4.MOTION DETECTION

-When MOTION DETECTION is set to ON, recording will start whenever a motion in the input video is detected.

[ON/OFF]

-Use , , , , key to make changes.

5.SENSITIVITY

-MOTION DETECTION SENSITIVITY can be set when user set the MOTION DETECTION. There are three stages -- HIGH/NORMAL/LOW. [HIGH/NORMAL/LOW]

-Use , , , , key to make changes.

6.MOTION CH SETUP

-Set the channel that you want to detect MOTION.

 

07/07/07

00:00:01

MOTION

CH SETUP

 

 

CAMERA1

AREA1

CAMERA2

OFF

 

CAMERA3

OFF

 

CAMERA4

OFF

 

CAMERA5

OFF

 

CAMERA6

OFF

 

CAMERA7

OFF

 

CAMERA8

OFF

 

 

 

 

 

You can divide the motion detection area into total 9 for each channel. The following screen displays to activate only No. 1 area of No. 1 channel.

You can use the direction key to move the area around and select FULL for the motion detection on the whole screen. With MOTION DETECTION set to ON, if motion is sensed in other areas where MOTION DETECTION is not set to ON, MOTION DETECTION will not operate.

-Motion is detected only from channels set to 'On'. The following screen shows motion recording after motion detection. A motion is deteced in the Channel 4. The 'M' mark before the title of each channel indicates that a motion is detected. [OFF/AREA1/AREA2/AREA3/AREA4/AREA5/ AREA6/AREA7/AREA8/FULL]

 

07/01/05

00:00:01

CAM1

CAM2

CAM3

 

 

 

M CAM4

CAM5

CAM6

 

 

 

CAM7

CAM8

 

 

 

 

5-7) TIMER RECORD MODE

TIMER : Set this option to ON to setup Timer Recording [ON/OFF].

DAY : Select the day of a week for the timer recording [MON, TUE, WED, THU, FRI, SAT, DAILY, SUN].

START & END : Set the starting and ending time for the timer recording [00:00 ~ 23:59].

FIELD RATE : Set the number of fields to be recorded per second [NTSC][1/2.5/3.75/7.5 IPS] [PAL][0.8/1.6/3.1/6.3 IPS].

Use , , , key to make change.

Caution

There are three types of recording modes: Event Re- cording (Motion Detection & Alarm), Timer Recording, and Normal Recording.

If all three recording modes are selected at the same time, recording takes place in the order of Event, Timer, and Normal.

Eng-22

Page 22
Image 22
Samsung SMT-190Dx user manual Timer Record Mode