Remote Setup

C

Setting the Alarm-Set

To set the alarm input/output conditions of the alarm input/output terminals.

bAlarm Out

Sets whether to output or not alarm signal from this unit.

bSetting an alarm input terminal

Specify an alarm input terminal number and set the type.

ON: Output enabled

OFF: Output disabled

bSetting an alarm output terminal

Specify an alarm output terminal number (1 - 4) and set the alarm output conditions.

1

2

3

4

5

6

1Alarm Out No.

Specifies the alarm output terminal number (1 - 4).

2Alarm In

Outputs an alarm signal when the specified external alarm input terminal receives an input.

Input terminal number DSR-2116: 1 -16,DSR-2108: 1 - 8

3Motion ON

Outputs an alarm signal when the specified video input terminal receives a motion detection signal.

Input terminal number DSR-2116: 1 -16,DSR-2108: 1 - 8

4Video Loss On

Outputs an alarm signal when a video loss occurs in the specified video input terminal.

Input terminal number DSR-2116: 1 -16,DSR-2108: 1 - 8

5HDD Error

Sets whether to output or not an alarm signal when a hard disk error occurs.

ON: Alarm signal output enabled

OFF: Alarm signal output disabled

6Alarm Duration

Sets the duration of the alarm output signal. (3 - 255 SECONDS)

1

2

1Alarm In No.

Specifies the alarm input terminal number.

Input terminal number DSR-2116: 1 -16,DSR-2108: 1 - 8

2Type

Sets the signal polarity of the specified alarm input terminal.

----:Alarm input detection disabled

N/O (Normal Open):

Normally open, detects input when closed

N/C (Normal Close):

Normally closed, detects input when opened

68

Page 75
Image 75
Sanyo DSR-2108 Setting the Alarm-Set, BAlarm Out, BSetting an alarm input terminal, BSetting an alarm output terminal