RECORD settings

B

ALARM (P18)

Recording is performed as soon as a sensor device connected to the external alarm input terminal (ALARM IN) of this unit reacts.

SCHEDULE (P19)

Recording is performed daily during the set time slot set on the TIMER SET screen in the recording settings.

DISABLE

No recording is performed.

Setting the MOTION ZONE (Refer to "MOTION recording": P17)

Select the zone where the motion sensor is active. It is necessary to set a detection frame when PARTIAL ZONE is selected.

FULL ZONE:

The motion sensor is active on the whole screen.

PARTIAL ZONE:

The motion sensor is active in the set detection frame.

Setting the MOTION SENSITIVITY

To select "MOTION SENSITIVITY" and select the level of detection sensitivity of the motion sensor.

Selections: 1/2/ ... 8/9 (Low sensitivity level)

Setting the ALARM RECORDING

Up to a maximum of 4 alarm input terminal numbers can be set to activate ALARM recordings.

ALARM recording is performed when an external alarm signal is input to the specified terminal.

Setting the PRE RECORD

To select "PRE RECORD" and select pre-recording.

ON: Starts recording approximately 5 seconds before the internal motion sensor or the external sensor detector is triggered. (with 1 ips frame rate)

OFF: No pre-recording

Setting the POST EVENT RECORD

To select "POST EVENT RECORD" and select in how much time, after the sensor detection, the recording will start.

Selections:

2 to 30 SECONDS, 1 to 5 MINUTES, 10 MINUTES, 15 MINUTES

Setting the AUDIO

To select "AUDIO" and set the audio sound recording.

ON: Records the audio of live videos

To listen to audio sound connect an external microphone or speaker.

OFF: Does not record the audio of live videos.

Only CH1 - CH4 can record AUDIO.

CSetting the TIMER SET

To perform SCHEDULE settings.

The recording schedule of each channel can be set using settings by the hour. (P19)

DSetting the REAL-TIME RECSET

To trigger recording using the Record/Stop button or an external alarm input, select "REAL-TIME REC SET", and perform the following settings for each channel using the control buttons ({}~).

FRAME RATE

Sets the recording speed for real-time recording. (OFF, NTSC: 1 - 30 IPS, PAL: 1 - 25 IPS)

QUALITY

Sets the image quality for real-time recording in 5 levels (NETWORK/ECONOMY/BASIC/NORMAL/FINE).

EVENT

Sets the alarm input terminal number that triggers a real-time recording.

Input terminals:

DSR-2116: ----, 1 - 16

DSR-2108: ----, 1 - 8

POST EVENT RECORD (Recording time)

Sets the duration of the real-time recording (--, 2 to 30 SECONDS, 1 to 5 MINUTES, 10 MINUTES, 15 MINUTES)

Memo: If "" is selected, recording is triggered when the Record button is pressed or whenever an alarm input occurs.

RECORD

 

 

 

RESOLUTION

FULL

CHANNEL

 

 

 

C1

FRAME RATE

1 ips

QUALITY

NORMAL

RECORDING

CONTINUOUS

MOTION ZONE

FULL ZONE

MOTION SENSITIVITY

9

 

ALARM RECORDING

-- -- -- --

PRE RECORD

OFF

POST EVENT RECORD

5 SECONDS

AUDIO

OFF

TIMER SET

 

 

 

REAL-TIME REC SET

 

 

 

REAL-TIME REC SET-CH1

FRAME RATE

1 ips

QUALITY

NORMAL

EVENT

--

-- -- --

POST EVENT RECORD

5

SECONDS

36

Page 43
Image 43
Sanyo DSR-2108 instruction manual Record settings