Configuring the Computing Unit in BIOS Setup

Release 04/02

 

 

 

Large Disk

[DOS]

The drive tables are adapted for DOS access operations

Access Mode

 

in accordance with Enhanced IDE.

 

[OTHER]

The tables are not adapted.

 

 

Memory Gap at

[Disabled] The complete onboard RAM memory is available.

15 MByte

[Enabled] A 1MB area of the RAM above 15MB

 

 

(Addresses F0 0000 – FF FFFF) can be used by ISA

 

 

expansion cards.

 

 

 

Submenu“COM/LPT Configuration”

 

 

 

 

 

 

 

 

PhoenixBIOS Setup Utility

 

 

 

 

Advanced

 

 

 

 

 

 

 

 

COM/LPT Configuration

 

 

Item Specific Help

 

Internal COM 1:

 

[Enabled]

 

Configure serial port A

 

 

Base I/O address:

[3F8]

 

using options:

 

 

 

 

 

 

 

 

Interrupt:

 

[IRQ 4]

 

[Disabled]

 

Internal COM2:

 

[Enabled]

 

 

 

 

 

No configuration

 

 

Base I/O address:

[2F8]

 

 

 

 

 

 

 

 

 

 

Interrupt:

 

[IRQ 3]

 

[Enabled]

 

 

Internal LPT1:

 

[Enabled]

 

 

User configuration

 

 

 

 

 

 

 

 

Mode:

 

[Output only]

[Auto]

 

 

 

Base I/O address:

[378]

 

 

 

 

 

 

BIOS or OS chooses

 

 

Interrupt:

 

[IRQ 7]

 

 

 

 

 

 

 

configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

[OS Controlled]

 

 

 

 

 

 

 

Displayed when

 

 

 

 

 

 

 

controlled by OS

 

F1

Help

Select Item

+ / –

Change Values

F9

Setup Defaults

 

ESC

Exit

Select Menu

Enter

Select

Sub-Menu

F10

Save and Exit

Figure 5-10

”COM/LPT Configuration” Submenu

 

 

 

 

The resources used by an interface are released when you disable the interface in question.

The I/O addresses and interrupts are preassigned to be operated as COM1, COM2 and LPT1 and we recommend you use them accordingly.

5-16

Panel PC 670 Computing Unit, Equipment Manual

Page 104
Image 104
Siemens PC 670 manual SubmenuCOM/LPT Configuration, Dos, Other