Siemens PC 670 manual Parallel interface LPT1

Models: PC 670

1 200
Download 200 pages 33.71 Kb
Page 145
Image 145

Release 04/02

Hardware Information

Parallel interface LPT1

The parallel interface (LPT1) of the computing unit is assigned as follows:

1

14

1325

Figure 7-3 Parallel interface LPT1 (female)

Pin No.

Short Name

Meaning

Input/Output

 

 

 

 

1

/ Strobe (CLK)

Data message

Output (open collector)

 

 

 

 

2

Data bit 0

Data line 0

Output (TTL level)

 

 

 

 

3

Data bit 1

Data line 1

Output (TTL level)

 

 

 

 

4

Data bit 2

Data line 2

Output (TTL level)

 

 

 

 

5

Data bit 3

Data line 3

Output (TTL level)

 

 

 

 

6

Data bit 4

Data line 4

Output (TTL level)

 

 

 

 

7

Data bit 5

Data line 5

Output (TTL level)

 

 

 

 

8

Data bit 6

Data line 6

Output (TTL level)

 

 

 

 

9

Data bit 7

Data line 7

Output (TTL level)

 

 

 

 

10

/ACK

Acknowledge

Input (4.7 kW pull up)

 

 

 

 

11

BUSY

Not ready

Input (4.7 kW pull up)

 

 

 

 

12

PE (PAPER END)

No paper

Input (4.7 kW pull up)

 

 

 

 

13

SELECT

Device selection

Input (4.7 kW pull up)

 

 

 

 

14

/ AUTO FEED

Automatic new line

Output (open collector)

 

 

 

 

15

/ ERROR

Device error

Input (4.7 kW pull up)

 

 

 

 

16

/ INIT

Reset / Initialization

Output (open collector)

 

 

 

 

17

/ SELECT IN

Printer selection

Output (open collector)

 

 

 

 

18 - 25

GND

Chassis ground

-

 

 

 

 