Technical Data

Release 04/02

 

 

 

A.1

Technical Data of the Panel PC 670 Computing Unit

 

 

 

 

 

General

 

 

 

 

 

 

 

 

Order nos.

 

See order documentation

 

 

 

 

Dimensions

 

297x267x80 (WxHxD in mm), without CD-ROM drive

 

 

297x267x101 (WxHxD in mm), with CD-ROM drive

 

 

 

 

Weight

 

approx. 6kg (13.5 lbs.)

 

 

 

 

Supply voltage (UN)

120 V (85 V to 132 V (AC),

 

 

 

or 230 V (170 V to 264 V) AC (autorange)

 

 

alternative: 24 V (20.4 bis 28.8 V) DC, SELV

 

 

 

 

(Line voltage frequency, AC

50/60 Hz

(47 to 63 Hz)

 

 

 

 

Short-term power interruption complying to to

max. 20 ms at 0.85 UN

 

Namur

 

(max. 10 times per hour; min. recovery time 1 s)

Max. power consumption

120W

 

 

 

 

 

max. current output (DC), according to form of

+5V/ 13,5A

 

power supply

3,3V/ 8,5A

 

 

 

 

 

 

 

 

+12V/ 2,5A

 

 

 

–12V/0,3A

 

 

 

 

(in total max. 105W)

 

 

 

 

Noise emission

< 55dB(A) to DIN 45635

 

 

 

 

 

Degree of protection

IP20

 

 

 

 

 

 

 

Safety

 

 

 

 

 

 

Protection class

Protection class I pursuant IEC 60536

 

 

Safety specifications with AC power supply

UL1950/IEC 60950 entspr. DIN VDE 0805, UL 508

 

 

 

 

Safety specifications with DC power supply

UL508

 

 

 

 

 

 

Electromagnetic compatibility (EMC)

 

 

 

 

 

Emitted interference with power supply 105W

EN 55022 Class A (requirement for industrial sector)

 

 

for devices with AC power supply EN6100-3-2 class D

 

 

and EN61000-3-3

 

Emitted interference with power supply 85W

EN 55022 Class B (requirement for domestic and

 

 

industrial sector)

 

 

 

for devices with AC power supply EN6100-3-2 class D

 

 

and EN61000-3-3

 

 

 

 

Noise immunity:

± 2 kV

(to IEC 61000-4-4; Burst)

Mains borne disturbance variables on supply

± 1 kV

(to IEC 61000-4-5; Surge symm)

lines

 

± 2 kV

(to IEC 61000-4-5; Surge unsymm)

 

 

 

Noise immunity on signal lines

± 1 kV

(IEC 61000-4-4; Burst; length < 5 m)

 

 

± 2 kV

(IEC 61000-4-4; Burst; length > 5 m)

 

 

± 2 kV

(to IEC 61000-4-4:1995; Surge unsymm;

 

 

 

length > 30 m)

 

 

 

 

Noise immunity to discharges of static electricity

± 6 kV contact discharge

(to IEC 61000-4-2)

 

 

± 8 kV discharge in air

(to IEC 61000-4-2)

 

 

Noise immunity to high-frequency radiation

10 V/m 80-1000 MHz, 80% AM (to IEC 61000-4-3)

 

 

10 V/m 900 MHz and 1,89 GHz, 50% ED

 

 

(to IEC 61000-4-3)

 

 

 

10 V 9KHz- 80MHz

(to IEC 61000-4-6)

 

 

 

Magnetic field

30 A/m 50Hz

(to IEC 61000-4-8)

 

 

 

 

 

A-2

Panel PC 670 Computing Unit, Equipment Manual

Page 178