Hardware Information

Release 04/02

 

 

 

MPI/DP interface

The MPI/DP port on the computing unit is assigned as follows:

1

6

5

9

Figure 7-7 PROFIBUS/MPI Socket Connector

Pin

Short Name

Meaning

Input/Output

No.

 

 

 

 

 

 

 

1

-

Not assigned

-

 

 

 

 

2

-

Not assigned

-

 

 

 

 

3

LTG_B

Signal lead B of MPI module

Input/Output

 

 

 

 

4

RTS_AS

RTSAS, control signal for

Input

 

 

received data stream. The signal

 

 

 

is ’1’ active when the directly

 

 

 

connected AS is sending.

 

 

 

 

 

5

M5EXT

M5EXT return line (GND) of the 5

Output

 

 

V power supply. The current load

 

 

 

caused by an external user

 

 

 

connected between P5EXT and

 

 

 

M5EXT must not exceed 90 mA.

 

 

 

 

 

6

P5 EXT

P5EXT supply (+5 V) of 5 V

Output

 

 

supply. The current load caused

 

 

 

by an external user connected

 

 

 

between P5EXT and M5EXT

 

 

 

must not exceed 90 mA.

 

 

 

 

 

7

-

Not assigned

-

 

 

 

 

8

LTG_A

Signal lead A of MPI module

Input/Output

 

 

 

 

9

RTS_PG

RTS output signal of the MPI

Output

 

 

module. The signal is ’1’ when

 

 

 

the PG is sending.

 

 

 

 

 

Shield

 

On connector casing

 

 

 

 

 

7-16

Panel PC 670 Computing Unit, Equipment Manual

Page 148
Image 148
Siemens PC 670 manual MPI/DP interface, Pin Short Name Meaning Input/Output