Siemens PC 670 manual Error Message Appears on the Screen/Display, Error messages

Models: PC 670

1 200
Download 200 pages 33.71 Kb
Page 126
Image 126

Fault Diagnosis

Release 04/02

 

 

 

6.7Error Message Appears on the Screen/Display

Error messages

The error messages issued by the system BIOS are listed below. Refer to the relevant program manuals in the case of error messages issued by the operating system or programs.

Press F2 during the boot routine to call in the Setup menu (refer to Chapter 5).

Error message on screen

Significance/Advice

 

 

Address conflict

Plug and Play Problem

 

Contact your technical service department.

 

 

Combination not supported

Plug and Play Problem

 

Contact your technical service department.

 

 

IO device IRQ conflict

Plug and Play Problem

 

Contact your technical service department.

 

 

Invalid System Configuration

Plug and Play Problem

Data

Set the RESET CONFIGURATION.DATA option in the Advanced

 

Setup menu.

 

Contact your technical service department.

 

 

Allocation Error for ...

Plug and Play Problem

Please revert the last hardware modification. Contact your technical service department.

System battery is dead

Battery on the CPU module is defect or empty.

Replace and run SETUP

Contact your technical service department.

 

 

System CMOS checksum bad

Call in SETUP, define settings and store. If this message appears

Run SETUP

during each boot routine, contact your technical service department.

 

 

Incorrect Drive A type

Check the SETUP entries for drive A.

Run SETUP

 

 

 

Incorrect Drive B type

Check the SETUP entries for drive B.

Run SETUP

 

 

 

Diskette drive A error

Fault accessing drive A

 

Contact your technical service department.

 

 

Diskette drive B error

Fault accessing drive B.

 

Contact your technical service department.

 

 

Failure Fixed Disk

Fault accessing the hard disk.

 

Check the SETUP settings

 

Contact your technical service department.

Keyboard error

Check that the keyboard is connected correctly.

 

 

Stuck Key

Check whether a key on the keyboard is jammed.

 

 

System RAM Failed at offset:

Memory error

 

Contact your technical service department.

 

 

Shadow RAM Failed at offset:

Memory error

 

Contact your technical service department.

 

 

Extended RAM Failed at offset:

Memory error

 

Contact your technical service department.

 

 

Failing Bits:

Memory error

 

Contact your technical service department.

 

 

6-6

Panel PC 670 Computing Unit, Equipment Manual

Page 126
Image 126
Siemens PC 670 Error Message Appears on the Screen/Display, Error messages, Error message on screen Significance/Advice