6.8Computing Unit Self-Test Prior to Booting

After switching on the SIMATIC PC a self-test is initiated (POST = Power On Self Test). If errors are detected during the POST, the corresponding sequence of POST beeps (beep code) are issued. Each beep code consists of 2 x 2 sequences.

In addition, the individual test steps which the self-test executes, are issued on the I/O port 80h.

Conversion table for the beep codes to hexadecimal representation:

 

 

 

Beeps

 

 

Hex Code

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

B

0

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

BB

1

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

BBB

2

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

BBBB

3

 

 

 

 

 

 

 

 

 

 

 

BB

 

 

 

 

B

4

 

 

 

 

 

 

 

 

 

 

 

BB

 

 

 

 

BB

5

 

 

 

 

 

 

 

 

 

 

 

BB

 

 

 

 

BBB

6

 

 

 

 

 

 

 

 

 

 

 

BB

 

 

 

 

BBBB

7

 

 

 

 

 

 

 

 

 

 

 

BBB

 

 

 

 

B

8

 

 

 

 

 

 

 

 

 

 

 

BBB

 

 

 

 

BB

9

 

 

 

 

 

 

 

 

 

 

 

BBB

 

 

 

 

BBB

A

 

 

 

 

 

 

 

 

 

 

 

BBB

 

 

 

 

BBBB

B

 

 

 

 

 

 

 

 

 

 

 

BBBB

 

 

 

 

B

C

 

 

 

 

 

 

 

 

 

 

 

BBBB

 

 

 

 

BB

D

 

 

 

 

 

 

 

 

 

 

 

BBBB

 

 

 

 

BBB

E

 

 

 

 

 

 

 

 

 

 

 

BBBB

 

 

 

 

BBBB

F

 

 

 

 

 

 

 

 

Example

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

BBB

BBB

 

B

 

Beeps

 

 

 

 

 

 

 

 

 

2

8

 

 

Hex Code

 

 

 

 

 

 

 

 

 

Test system memory

 

 

Meaning

 

 

 

 

 

 

 

 

 

Special codes

In addition to the beep codes listed below, there are also special codes:

3x short

INSERT button has been pressed during the system start:

 

The Onboard Device Installation is skipped. The Onboard

 

Graphic is used as the standard output.

1x long 8x short

Fault reading the MPI system information:

 

Contact your technical service department.

4x short

MPI EPROM was programmed for the first time.

1x long 5x short

Ethernet error: Contact your technical service department.