Siemens PC 670 Environmental conditions, Mechanical environmental conditions, Special Features

Models: PC 670

1 200
Download 200 pages 33.71 Kb
Page 179
Image 179

Release 04/02

Technical Data

Environmental conditions

Temperature

 

tested to DIN EN 60068-2-2:1994, DIN IEC 60068-2-1,

 

 

 

DIN IEC 60068-2-14,

operation

 

+5 °C to +45 °C

storage/transport

 

- 20°C to +60°C

gradient

 

max 10°C/h (no condensation)

 

 

 

Relative humidity

 

tested to DIN IEC 60068-2-3, DIN IEC 60068-2-30,

 

 

 

DIN IEC 60068-2-56

operation

 

5% to 80% at 25°C (no condensation)

storage/transport

 

5% to 95% at 25°C (no condensation)

gradient

 

max 10°C/h (no condensation)

 

 

 

 

Mechanical environmental conditions

 

 

 

 

Vibration *)

 

tested to DIN IEC 60068-2-6

operation

 

10 to 58 Hz: 0.075 mm, 58 to 500 Hz: 9.8 m/s2

storage/transport

 

5 to 9 Hz: 3,5 mm, 9 to 500 Hz: 9.8 m/s2

Shock

 

tested to DIN IEC 60068-2-29

operation

 

50 m/s2, 30 ms,

storage/transport

 

250 m/s2, 6 ms,

Special Features

 

 

 

 

Quality assurance

 

to ISO 9001

 

 

 

 

Mainboard

 

 

 

 

Processor

 

Intel Pentium III / Celeron (see order documentation)

 

 

 

Internal processor cache

 

2x 16KB first level, 128/256/512 KB second level,

 

 

 

dependent on the processor used

 

 

 

Main memory

 

maximum 512 MB SDRAM,

 

 

 

memory configuration (see order documentation)

2. Level Cache

 

Processor internal

 

 

 

Free expansion slots

 

1 shared ISA/PCI (max 175 mm long),

 

 

 

1 PCI (max 265mm long)

 

 

 

 

– max. permissible current input per ISA slot

 

5V

2A, 12V 0.3A, -12V 0.1A

– max. permissible current input per PCI slot

 

5V

2A, 12V 0.3A, -12V 0.1A

– in total (all slots)

 

5V 3A, 12V 0.6A, -12V 0.15A may not be exceeded

 

 

 

 

Drives

 

 

 

 

Floppy disk/LS240 drive

 

3.5” (1.44 MB) / 3.5” (240 MB, 120 MB or 1.44 MB)

 

 

 

Hard disk

 

3,5”, EIDE, UDMA33, hard disk capacity (see order

 

 

 

documentation)

 

 

 

CD-ROM-/CD-RW-/DVD(Combo) drive

 

650 MB / 4.7 GB

 

 

 

*)

Restrictions for LS 240 with 120/240 MB data carrier and CD ROM /CD RW /DVD

 

10 to 58 Hz: 0.019 mm, 58 to 500 Hz: 2.5 m/s2

 

 

Panel PC 670 Computing Unit, Equipment Manual

A-3

Page 179
Image 179
Siemens PC 670 manual Environmental conditions, Mechanical environmental conditions, Special Features, Mainboard, Drives