Operating Manual U42093-J-Z716-1-74
Mounting the PSFR-CP41 in a Rack Installing the PSFR-CP41
Fibre Channel connection
SCSI Connection
The PSFR-CP41 supports Fast/Ultra Wide SCSI. The PSFR-CP41 is factory
configuredto suppor t Differential SCSI bus.Two 68-pin D-shell connectors are
located on therear panel of the unit, allowing the unit to be attached in the
middleor at the end of a SCSI bus. If the PSFR-CP41 is located at one end of
the SCSI bus,an external terminator should be installed. A terminator is
provided withthe PSFR- CP41.
The PSFR-CP41 suppliester mination power(TERMPWR) on the SCSI bus. A
self-resettingfuse is used that will reset after the fault is cleared.
Fig. “Fibre Channel connection”
showsthe F ibreC hannelpor t on the
back of thePSF R-CP41.
S
CSI DIFF Di
ff
erential
SCS
Isupport is indicated by this symbol on the
rear of the 6100.