Port Statuses in DMode C

Installation and Commissioning

Port Statuses in DMode C

In display mode C, the current mode (half duplex, full duplex) is indicated.

Port

Color

Status

Meaning

 

 

 

 

P1

 

off

Port operating in half duplex

P2

 

 

 

P3

 

 

 

P4

 

 

 

 

Green

on

Port operating in full duplex

 

 

 

 

F

IN1/IN5

RM

P1

L1

IN2/IN6

STBY

P2

L2

IN3/IN7

DM1

P3

 

IN4/IN8

DM2

P4

PowerModuleLEDs

DI-LEDs

CPU-LEDs

Port-LEDs

Figure 6-31 Mode display (full/half duplex) of port 1

Note

If there is a link fault and the type of transmission is fixed (autonegotiation off), in DMode C, the desired status, in other words the set type of transmission (full or half duplex) continues to be displayed. If there is a link fault and autonegotiation is active, the port LED goes off.