6.1.1Installing / Uninstalling with an S7-300 Rail

Installing on an S7-300 Rail

For installation, you require a slotted screwdriver with a 5.5 mm wide blade.

Notice

When installing the SCALANCE X414-3E, hold it by the backplane and not by the modules, otherwise the device may be damaged.

To install the device, follow the steps below:

1.Tilt the basic device slightly towards the back with the upper groove on the edge of the S7-300 rail and push in towards the bottom. In this position, the basic device should not slip off but it can be adjusted horizontally to the left or right until the required position is achieved.

2.Remove the covers from slots 7 and 9 (see section 6.2.2) and the dummy cover from slot 8 (see section 6.2.3). If media modules are inserted, remove the fast Ethernet media module instead of the cover from slot 7 (see section 6.2.1).

3.Using a screwdriver with a 5.5 mm wide blade, tighten the two captive screws in the backplane at slot 7 and between slots 8 and 9 until the basic device can no longer be moved to the side.

Note

Only horizontal installation permitted (ventilation slit top/bottom).