Product Description of SCALANCE X-400

Startup Behavior

 

C-PLUG

X414-3E Startup

 

 

 

1

not found

with internal configuration (if it exists)

 

 

or with factory defaults.

 

 

 

2

empty

with internal configuration, immediately

 

 

copies this automatically to the C-

 

 

PLUG.

 

 

 

3

written with own X414-3E configu-

with C-PLUG configuration.

 

ration data.

 

 

 

 

4

written with third-party X414-3E

with third-party C-PLUG configuration.

 

configuration data.

 

 

 

 

5

written with configuration data of a

with internal configuration, red LED on

 

different device type.

power module and log entry.

 

 

 

6

defective

with internal configuration, red LED on

 

 

power module and log entry.

 

 

 

In cases 1 and 2, the configuration data on the Switch CPU and the C-PLUG is identical. In cases 3 and 5 the configuration data is different and can be synchro- nized manually. In case 6, you can attempt to reformat the C-PLUG with the clean function. If problems persist, replace the C-PLUG.

Notice

In case 4 (replacing the switch), the DIL switch settings of the C-PLUG and not the physical switch settings are adopted. A deviation is signaled by the diagnostic op- tions.

For more detailed information, refer to the SCALANCE X-400 Configuration Man- ual.