Technical Specifications

7

 

7.1

SCALANCE X414-3E

 

 

 

 

 

 

 

Interfaces

 

 

 

Connecting end devices or network

2 x RJ-45 jack (10/100/1000 Mbps)

 

 

segments over twisted pair

12 x RJ-45 jack (10/100 Mbps)

 

 

 

All electrical ports support autonegotia-

 

 

 

tion and autocrossover.

 

 

Installation of media modules

2 x slot (6 and 7) for media module

 

 

 

types MM491-2 and MM491-2LD

 

 

 

1 x slot (5) for media module types

 

 

 

MM492-2 and MM492-2LD

 

 

Installation of extender modules

1 x slot for extender module

 

 

 

EM495-8 or EM496-4

 

 

Connector for power supply and signal-

2 x 4-pin plug-in terminal blocks

 

 

ing contact

 

 

 

Connection of digital inputs

2 x 5-pin plug-in terminal blocks

 

 

 

 

 

 

Power supply

2 power supplies 24 V DC (20.4 to

 

 

(redundant inputs isolated)

28.8 V) safety extra-low voltage

 

 

 

(SELV)

 

 

 

Power supply voltage connected over

 

 

 

high resistance with housing (not elec-

 

 

 

trically isolated).

 

 

 

Tested to IEC 6100-4-5, 1995 "Surge

 

 

 

Immunity Test“, performed with light-

 

 

 

ning protection device DEHN Blitzduc-

 

 

 

tor VT AD 24V, article no. 918 402 is

 

 

 

used

 

 

Power consumption (without modules)

15 W

 

 

at 24 V DC

 

 

 

Current consumption at 24 V DC

< 2000 mA

 

 

 

 