Siemens X-400 Installing / Removing Extender Modules, Installation and Commissioning

Models: X-400

1 148
Download 148 pages 53.7 Kb
Page 76
Image 76
6.3Installing / Removing Extender Modules

Installation and Commissioning

6.3Installing / Removing Extender Modules

6.3.1Installing / Removing the Twisted Pair Extender

Installing the Twisted Pair Extender on the S7-300 Rail

You require the following tools:

slotted screwdriver with a 2.8 mm wide blade

slotted screwdriver with a 5.5 mm wide blade

Note

Make sure that in addition to the extender width of 87 mm, there is a clearance of 20 mm to the right of the basic device on the S7-300 rail to be able to align the guide bolts of the extender with the holes in the basic device during installation.

When installing a twisted pair extender on an S7-300 rail, the basic device remains in position. Follow the steps below:

1.Remove the cover from slot 11 of the basic device.

2.Remove the right-hand side panel of the basic device. To do this, use a slotted screwdriver with a 2.8 mm wide blade to loosen the two captive slug screws on slot 11 in the upper and lower recesses as far as they will go.

3.Remove the side panel of the basic device from the basic device to the right.

Note

Keep the panel in a safe place in case the extender needs to be removed again later.

4.Remove the two covers from the extender.

5.Place the extender module on the edge of the S7-300 rail with the upper groove angled slightly towards the back and tilt the extender towards the back. Make sure that there is adequate clearance between the guide bolts of the ex- tender module and the basic device. In this position, the extender module should not be able to slip off, however it can be moved horizontally in both di- rections.

76

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches

C79000-G8976-C186-03

Page 76
Image 76
Siemens X-400 Installing / Removing Extender Modules, Installing / Removing the Twisted Pair Extender