Siemens X-400 Ports, Power Supply Connectors, Polarity Reversal Protection, X1 X2

Models: X-400

1 148
Download 148 pages 53.7 Kb
Page 90
Image 90
6.6Ports

Installation and Commissioning

6.6Ports

6.6.1Power Supply Connectors (X1)

Polarity Reversal Protection X1, X2

The two 4-pin male connectors (X1, X2) for the power supply and the signaling contact have no polarity reversal protection. If the connectors are accidentally swapped over, this does not cause damage or destroy circuits. Normal functionality is, however, not available while the connectors are swapped over.

The redundant power supply is connected over a 4-pin connector at the front ter- minal block on the power module.

X1

X2

L2 M2 M1 L1

Figure 6-9 Pin assignment of connector X1

Conn. 1

L1+

+ 24 V power supply 1

 

 

 

 

M1

Ground

 

 

 

 

M2

Ground

 

 

 

 

L2+

+ 24 V power supply 2

 

 

 

90

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches

C79000-G8976-C186-03

Page 90
Image 90
Siemens X-400 Ports, Power Supply Connectors, Polarity Reversal Protection, Installation and Commissioning, X1 X2