Siemens X-400 Removing the Media Module Extender from the S7-300 Standard Rail

Models: X-400

1 148
Download 148 pages 53.7 Kb
Page 84
Image 84
Removing the Media Module Extender from the S7-300 Standard Rail

Installation and Commissioning

Removing the Media Module Extender from the S7-300 Standard Rail

You require the following tools:

slotted screwdriver with a 2.8 mm wide blade

slotted screwdriver with a 5.5 mm wide blade

Note

To remove the extender, remove the media modules from slots 13 and 14.

When removing a media module extender from an S7-300 rail, the basic device remains in position. Follow the steps below:

1.To remove an extender module, use a slotted screwdriver with a 5.5 mm wide blade, to open the captive screw between slots 13 and 14 in the lower part of the extender module.

2.Remove the cover from slot 11 of the basic device.

3.Use a slotted screwdriver with a 2.8 mm wide blade to loosen the two captive slug screws on slot 11 of the basic device in the upper and lower recesses as far as they will go.

4.Push the extender module slowly to the right while keeping it straight until the two guide bolts of the extender module are completely outside the holes in the basic device.

5.Pull out the lower part of the extender module slightly towards the front and lift it from the S7-300 rail.

6.Replace the right side panel of the basic device so that the guide bolts fit into the two holes in the basic device.

7.Using a slotted screwdriver with a 2.8 mm wide blade, tighten the two captive slug screws on slot 11. The screws lock the two guide bolts, so do not use ex- cessive force when tightening them.

8.Fit a suitable cover on slot 11 of the basic device.

Note

The basic device must not be used permanently without the right side panel.

84

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches

C79000-G8976-C186-03

Page 84
Image 84
Siemens X-400 Removing the Media Module Extender from the S7-300 Standard Rail, Installation and Commissioning