Glossary

MDI

Medium Dependent Interface, - straight

 

On an MDI port or MDI cable, the receive (Rx) and the send (Tx) leads

 

are not crossed.

MDI-X

Medium Dependent Interface – crossover,

 

On an MDI-X port or MDI-X cable, the receive (Rx) and the send (Tx)

 

leads are crossed.

MIB

Management Information Base. The MIB is a formal description of net-

 

work objects in the form of a tree structure that contains all the relevant

 

information for network management in SNMP.

Mirroring

A port (mirror port) with its specific data traffic can be mirrored to an-

 

other port (monitor port) for test purposes. Protocol analysis devices

 

can be connected to the monitor port, in other words, the monitor port

 

is not available for data exchange. Mirroring has no effect on the mirror

 

port.

Modes

Modes are discrete waves used to transmit data within a fiber-optic

 

cable. With single mode fibers, only one wave propagates, whereas in

 

multimode fibers several waves propagate. Modes are patterns of elec-

 

tromagnetic fields in FOCs.

Multimode

In multimode transmission, the pulse is transferred using many modes

 

(waves) that travel along curved paths or are reflected within the core.

 

Attenuation is mainly caused by physical absorption and dispersion as

 

well as by mechanical bending. The amount of attenuation depends

 

among other things on the wavelength of the input light. Multimode

 

fiber-optic cables have an outer diameter of 125 µm and 50 or 62.5 µm

 

core diameter. Due to the larger core diameter the pulse edges de-

 

grade more than in single mode transmission resulting in shorter

 

transmission distances.

OSM

Optical Switching Module – SIMATIC NET Ethernet switch with optical

 

ports.

Rapid spanning tree The Rapid Spanning Tree protocol (RSTP) allows redundant transmis- sion paths. This prevents circulating frames and, if a fault develops, provides an alternative path within one second (reconfiguration time).

Reconfiguration time The time required to restore a functional configuration if a device fails or a network cable is interrupted.

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches

141

C79000-G8976-C186-03

Page 141
Image 141
Siemens X-400 technical specifications Mirroring, Modes, Multimode