Approvals, Certificates Glossary, Index
Preface, Contents
SIMATIC NET
Classification of Safety-Related Notices
Danger
Trademarks
Safety Instructions Regarding your Product
C79000-G8976-C186-03
Personnel Qualification Requirements
Correct Usage of Hardware Products
Correct Usage of Software Products
C79000-G8976-C186-03
C79000-G8976-C186-03
Purpose of the Operating Instructions
Preface
Validity of the Operating Instructions
Standards and Approvals
Further Documentation
Preface
Installation and Commissioning
Contents
Introduction to Industrial Ethernet Switches
System Description of SCALANCE
Contents
Index
1.1 Basic Information
Industrial Ethernet Switches
Introduction to
Switching
Introduction to Industrial Ethernet Switches
The Need for Industrial Ethernet Switches
Technical Options network topologies
1.2.1 Ring with Redundancy Manager
1.2 Topologies
Introduction to Industrial Ethernet Switches
Functional Description
Electrical Ring
Introduction to Industrial Ethernet Switches
Optical Ring
Figure 1-1 Gigabit ring with redundancy manager RM
Configuration Example
Introduction to Industrial Ethernet Switches
Figure 1-2 Ring with FO cable and redundancy manager
Functional Description
Introduction to Industrial Ethernet Switches
1.2.2 Star Structure
Properties of a Star Structure
Figure 1-3 Star structure Electrical
Configuration Example
Introduction to Industrial Ethernet Switches
Figure 1-4 Star structure Optical
1.2.3 Line Structure
Configuration Example
Introduction to Industrial Ethernet Switches
Functional Description
10/100
Introduction to Industrial Ethernet Switches
1.2.4 Redundant Linking of Network Segments
Mbit/s
Introduction to Industrial Ethernet Switches
The two devices connected in the configuration exchange data frames with each other to synchronize their operating statuses one device is master and the other slave. If there are no problems, only the link from the master to the other network segment is active. If this link fails for example due to a link-down or a device fail- ure, the slave activates its link as long as the problem persists
2.1 Properties, Functionality and Features of SCALANCE
System Description of SCALANCE
System Description of SCALANCE
C-PLUG
Component
Components of SCALANCE
System Description of SCALANCE
Function
Transmission Rate
2.2 Ports of SCALANCE
2.2.1 10Base-T / 100Base-TX
Transmission Mode
Transmission range
Connectors
Transmission medium
System Description of SCALANCE
Transmission Mode
Connectors
Transmission Rate
Transmission Medium
Transmission Mode
2.2.3 100Base-FX
Transmission Rate
Transmission Medium
Transmission Range
Connectors
BFOC connectors are used
System Description of SCALANCE
Transmission Mode
Connectors
Transmission Rate
Transmission Medium
Transmission Mode
Connectors
Transmission Rate
Transmission Medium
System Description of SCALANCE
2.3 Compatibility of SCALANCE
Compatibility List
End devices
System Description of SCALANCE
C79000-G8976-C186-03
3.1 SCALANCE X414-3E Basic Device
Product Description of SCALANCE
Overview
Figure 3-2 Basic device with media modules and covers
Product Description of SCALANCE
C79000-G8976-C186-03
Components of the Product
Product Description of SCALANCE
Spares
Power Module
Switch CPU
Slots
Slot
Product Description of SCALANCE
Slot
Slot
Figure 3-4 Ports of the SCALANCE X414-3E
Product Description of SCALANCE
STBY
3.1.1 Power Module
Product Description of SCALANCE
Change to the DIL switch during operation
Signaling Contact
Failure of the power supply
Product Description of SCALANCE
DI Module
3.1.2 Digital Inputs
Product Description of SCALANCE
3.1.3 Switch CPU
Product Description of SCALANCE
Ethernet Port
Serial Port
Product Description of SCALANCE
How It Works
3.1.4 C-PLUG Configuration Plug
Area of Application
Product Description of SCALANCE
Diagnostics
Product Description of SCALANCE
C-PLUG
Startup Behavior
Product Description of SCALANCE
X414-3E Startup
STBY
Product Description of SCALANCE
Figure 3-10 Ports on the basic device
P1 P1 P1 P2 P2 P2 P3 P3 P3 P4 P4 P4
Product Description of SCALANCE
C79000-G8976-C186-03
Procedure
Media Modules, Covers, Dummy Cover
4.1 Media Modules
Available Module Types
Options for Slots 6 and
Options for Slot
Media Modules, Covers, Dummy Cover
Properties
Connector
4.1.1 Fast Ethernet Media Module MM491-2 100Base-FX
LED Display of the Fast Ethernet Media Module
Properties
Connector
4.1.2 Fast Ethernet Media Module MM491-2LD 100Base-FX
LED Display of the Fast Ethernet Media Module
Properties
Connector
4.1.3 Gigabit Media Module MM492-2 1000Base-SX
LED Display of the Gigabit Media Module
Properties
Connector
4.1.4 Gigabit Media Module MM492-2LD 1000Base-LX
LED Display of the Gigabit Media Module
Slots of the Covers
4.2 Covers, Dummy Cover
4.2.1 Covers
Available Cover Types
Media Modules, Covers, Dummy Cover
CV490
Displays of the Cover
Figure 4-7 Slot 5 for cover CV490
Further Slots for the CV490 2x100 Cover
CV490
Displays of the Cover
Media Modules, Covers, Dummy Cover
Further Slots for the CV490 4x100 Cover
CV490
Displays of the Cover
Media Modules, Covers, Dummy Cover
Displays of the Dummy Cover
4.2.2 Dummy Cover
Slot of the Dummy Cover
Media Modules, Covers, Dummy Cover
Media Modules, Covers, Dummy Cover
C79000-G8976-C186-03
5.1 Twisted Pair Extender EM495-8
Extender Modules
Eight Additional 100Base-TX Ports
Figure 5-2 Twisted pair extender EM495-8
Covers
Extender Modules
C79000-G8976-C186-03
Four Additional Slots for Media Modules
5.2 Media Module Extender EM496-4
Connector
Extender Modules
Extender Modules
Covers
C79000-G8976-C186-03
Extender Modules
C79000-G8976-C186-03
Extender Modules
C79000-G8976-C186-03
Installation and Commissioning
6.1 Installing / Removing the SCALANCE X414-3E
Installing on an S7-300 Rail
6.1.1 Installing / Uninstalling with an S7-300 Rail
Installation and Commissioning
Installation and Commissioning
Removing from the S7-300 rail
Installation on a 35 mm Standard Rail
6.1.2 Installing / Uninstalling with a 35 mm Standard Rail
Installation and Commissioning
Figure 6-2 Installation on a 35 mm standard rail
Installation and Commissioning
Removing from the 35 mm Standard Rail
Installing a Media Module
6.2 Installing / Removing the Media Modules, Covers and Dummy Cover
6.2.1 Installing / Removing a Media Module
Installation and Commissioning
Installation and Commissioning
Removing a Media Module
Fitting a Cover
Installation and Commissioning
Variants of the Covers
Removing a Cover
Fitting a Dummy Cover
Installation and Commissioning
6.2.3 Fitting / Removing a Dummy Cover
Removing a Dummy Cover
Installing the Twisted Pair Extender on the S7-300 Rail
6.3 Installing / Removing Extender Modules
6.3.1 Installing / Removing the Twisted Pair Extender
Installation and Commissioning
Installation and Commissioning
Figure 6-4 Installing the twisted pair extender on the S7-300 rail
Installation and Commissioning
Removing the Twisted Pair Extender from the S7-300 Rail
Installing the Twisted Pair Extender on the 35 mm Standard Rail
Installation and Commissioning
Installation and Commissioning
Installation and Commissioning
Removing the Twisted Pair Extender from the 35 mm Standard Rail
Installing the Media Module Extender on the S7-300 Rail
6.3.2 Installing / Removing the Media Module Extender
Installation and Commissioning
Installation and Commissioning
Figure 6-6 Installing the media module extender on the S7-300 rail
Installation and Commissioning
Removing the Media Module Extender from the S7-300 Standard Rail
Installing the Media Module Extender on the 35 mm Standard Rail
Installation and Commissioning
Installation and Commissioning
Installation and Commissioning
Removing the Media Module Extender from the 35 mm Standard Rail
Specifying the Slot Number
6.4 Slot Numbers of the Modules and Covers
Installation and Commissioning
Applying the Slot Numbers
Installation and Commissioning
6.5 Factory Defaults
DIL Switches
Further Device Properties
Installation and Commissioning
6.6 Ports
6.6.1 Power Supply Connectors
Polarity Reversal Protection
Figure 6-10 Pin assignment of connector
6.6.2 Connectors of the Signaling Contact and Grounding Strap
Installation and Commissioning
X1 X2
Figure 6-11 Pin assignment of connector X1 Inputs 1 through
6.6.3 Digital Input Connectors
Installation and Commissioning
Polarity Reversal Protection X1
Figure 6-12 Pin assignment of connector X1 Inputs 5 through
6.6.4 Digital Input Connectors
Installation and Commissioning
X1
X414-3E
Installation and Commissioning
The FastConnect Cabling System
A=10m
Connecting TP Cord to FC Cable
Installation and Commissioning
Figure 6-15 IE FC RJ-45 Modular Outlet Insert 2FE
Installation and Commissioning
C79000-G8976-C186-03
A1 A1 A1
Installation and Commissioning
X414-3EX208
B A2 A2
Installation and Commissioning
Removing the FC Cable from SCALANCE X414-3E
Installation and Commissioning
6.6.6 Connectors for Fiber-Optic Cables
Gigabit Transmission with FOC
Fast Ethernet Transfer with FOC
Installation and Commissioning
Figure 6-19 BFOC plug with fast Ethernet media module MM491-2
Installation and Commissioning
6.7 Operator Controls
6.7.1 DIL Switches
Figure 6-20 Power module, digital inputs and Switch CPU with controls
Status
Installation and Commissioning
Switch
Meaning
Installation and Commissioning
Ring Ports in Slots 5 to
Switch2
Possible Settings of the Ring Ports
Switch1
Switch3
Defining the fault mask and the LED displays
Installation and Commissioning
Resetting to the factory defaults
6.7.2 SELECT / SET Button
Overview
6.8 LED Display
Installation and Commissioning
Display
LED off
Installation and Commissioning
LED on
LED flashes
STBY
6.8.2 Selecting the Display Modes
STBY
STBY
STBY
Display Modes A through C
IN1/IN5
IN2/IN6
IN2/IN6
Display in Display Mode D
IN1/IN5
STBY
IN2/IN6
LED Display of the Digital Inputs 1 through
IN1/IN5
STBY
6.8.5 LED Display - Switch CPU
Display Modes A through D
IN2/IN6
Port Statuses in DMode A
IN1/IN5
STBY
IN2/IN6
Port Statuses in DMode B
IN1/IN5
STBY
IN2/IN6
Port Statuses in DMode C
IN1/IN5
STBY
IN2/IN6
Port Statuses in DMode D
IN1/IN5
STBY
Removing the C-PLUG
6.9 Replacing the C-PLUG
Installation and Commissioning
Inserting the C-PLUG in the Slot
Installation and Commissioning
6.10 Show Location
Determining the Location of a SCALANCE
SCALANCE X414-3E
Technical Specifications
Interfaces
Interfaces
Technical Specifications
Switching Properties
C-Plug
Permitted Environmental Conditions
Technical Specifications
MTBF information mean time between failure
Construction
112,4
Technical Specifications
Dimension drawing - SCALANCE X414-3E
109,5
Interfaces
7.2 Media Module MM491-2 100Base-FX
Technical Specifications
Permitted Cable Lengths
Interfaces
7.3 Media Module MM491-2LD 100Base-FX
Technical Specifications
Permitted Cable Lengths
Interfaces
7.4 Media Module MM492-2 1000Base-SX
Technical Specifications
Permitted Cable Lengths
Interfaces
7.5 Media Module MM492-2LD 1000Base-LX
Technical Specifications
Permitted Cable Lengths
Interfaces
Extender Module EM495-8
Technical Specifications
Permitted Cable Lengths
107,5
112,4
109,5
87,6
Interfaces
Extender Module EM496-4
Technical Specifications
Permitted Environmental Conditions
112,4
Technical Specifications
Dimension drawing - extender module EM496-4
109,5
Approvals, Certificates
CE Marking
Required FDA and IEC labels
EMC Directive
Explosion Protection Directive
Approvals, Certificates
Note for the Manufacturers of Machines
Installation Guidelines
Directive on Machines
Approvals, Certificates
UL Approval Industrial Control Equipment
Note for Australia
UL Approval Information Technology Equipment
CSA Approval Information Technology Equipment
cULus Approval Hazardous Location
cULus Approval Information Technology Equipment
cULus Approval Industrial Control Equipment
Approvals, Certificates
ATEX Approval
FM Approval
Approvals, Certificates
Certification
Approvals, Certificates
Approvals, Certificates
C79000-G8976-C186-03
Autocrossover
Glossary
Aging time
Autonegotiation
Digital input
Fault mask
Glossary
Dispersion
Mirroring
Glossary
MDI-X
Modes
Ring port
Signaling Contact
Glossary
Segment
TELNET
Glossary
Store and forward
TP Port
Glossary
C79000-G8976-C186-03
Index
Standby function
Switching
Index
Status as shipped
A&D Technical Support
Worldwide, available 24 hours a day
Service & Support on the Internet
A&D Technical Support