2.14 Version Read of Periodically Replaced Units
The condition (new or used) of the I/D, fuser unit and belt unit are determined by an internal fuse within the units. When the unit is powered on or the upper cover is opened and closed, the printer scans for consumables fuses. If a conducting fuse is found, that unit's counter is reset and the fuse is opened. The life counters of the consumables are checked at each power on and each closing of the upper cover. Once a fuse is opened the consumable is judged used.
2.15 Life Counter for Replaceable Units
Each life of the periodically replaced units - I/D, fuse unit and belt unit is counted as shown in the following table:
Unit Name | Condition | Action |
|
|
|
I/D | The number of drum revolutions is counted in the unit of letter | Warning (the unit can still be used). |
| paper length + paper interval in continuous printing. |
|
| End of Life: Time when a distance equivalent to pages of 26K is |
|
| printed (on 3P/J). |
|
|
|
|
Toner Cartridge | The number of dots printed is counted. The used amount is | Do not use the unit anymore. |
| determined based on the counter value (See Section 2.16). |
|
| End of Life: Time when a |
|
|
|
|
Belt Unit | The number of turns revolutions is counted in the unit of letter | Warning (the unit can still be used). |
| paper length + paper interval in continuous printing. |
|
| End of Life: Time when the counter value reaches 80K. |
|
|
|
|
Fuser Unit | One is counted every time when one page is passed. | Warning (the unit can still be used). |
| End of Life: Time when the counter value reaches 80K. |
|
|
|
|
2.16 Toner Consumption Detection
The used toner amount is detected by counting the number of dots printed.
The counting starts after
When the equivalent of pages of 1K on A4 and 5% duty is reached after that,
41388601TH Rev.2 | 40 / |