2.6Color Misalignment Correction
C9000 is equipped with multiple LED heads, which can result in color misalignment. The mechanically induced color misalignment is automatically corrected as follows:
(1)Color alignment to be corrected
1 Color misalignment in
2 Color misalignment in slanting direction (Positional error caused by LED head)
3 Color misalignment in
(2)Correcting
Printing the preset color misalignment detection pattern on the belt and, by a reflection sensor, reading the printed pattern detects each color’s misalignment value to determine its correction value. The correction value is used to change each color’s (Cyan, Magenta and Yellow) writing timing in comparison with that of Black.
2.7Transfer Control Responds to Environmental Changes (Room Temperatures and Relative Humidities)
C9000 measures room temperature and relative humidity using a room temperature sensor and humidity sensor, and calculates an optimum transfer voltage under its measurement environment to perform