Trouble Check

Symptom

Cause and/or Corrective Actions

The date or time indicator is flashing.

You pressed DATE(+) and TIME(NEXT) together for more

than 2 seconds.

mThe camcorder is not malfunctioning.

You may start recording. Flashing will stop soon.

Thedateortimeindicator

mReset the date and time. (p. 38)

disappears.

 

 

 

 

 

 

 

 

 

 

 

Recordingstopsinafew

• START/STOP MODE is set to

 

or 5 SEC.

seconds.

mSet it to . (p. 31)

 

 

 

 

 

 

Picture

Symptom

Cause and/or Corrective Actions

The image on the viewfinder

• The viewfinder lens is not adjusted.

screen is not clear.

mAdjust the viewfinder lens. (p. 13)

A vertical band appears when a

• The contrast between the subject and background is too high.

subject such as lights or a

mThe camcorder is not malfunctioning. Change locations.

candle flame is shot against a

 

dark background.

 

 

 

The picture is “noisy”.

• The video heads may be dirty.

 

mClean the heads using the Sony V8-25CLH cleaning

 

cassette. (p. 46)

Others

Symptom

Cause and/or Corrective Actions

The supplied Remote

• COMMANDER is set to OFF.

Commanderdoesnotwork.

mSet it to ON. (p. 34)

Something is blocking the infrared rays. mRemove the obstacle.

The battery is not inserted with the correct polarity. mInsert the battery with the correct polarity. (p. 63)

The batteries are dead.

mInsert new ones. (p. 63)

There is dust in the viewfinder. mDetach the eyecup and clean the viewfinder lens. (p. 47)

52

CCD-TR401E/TR402E3-858-958-11(1).E,R