Insert a tape for recording.

AC timer recording

By connecting this unit to an external AC timer (not supplied), you can start recording at a preset time.

1 Connect this unit to an external AC timer (not supplied).

DSR-45/45P (rear panel)

Recording source (external tuner, etc.)

VIDEO IN REF. IN

AC timer

to an AC outlet

2

3 Set the INPUT SELECT selector of this unit to select the input signal.

4 Set the TIMER selector on the front panel of this unit to REC.

5 Set the timer-on time on the connected AC timer.

At the preset time, the power of this unit turns on automatically and recording starts after a few seconds (no more than 30). Set the timer allowing a margin for the recording to start. You do not need to press the REC button.

Note

When you intend to turn the unit off, press the STOP button on this unit to stop the tape transport operation beforehand.

If you turn the unit off while a tape is running, for example, by using an AC timer, the unit or the tape may be damaged.

If the tape ends before the recording source stops operation

The tape stops.

To stop recording during timer recording

Press the STOP button on this unit.

To release the AC timer recording mode

Set the TIMER selector on the front panel of this unit to OFF.

Recording and Playback 2 Chapter

Chapter 2 Playback and Recording

45 (GB)