•When the COUNTER SELECT selector on the front panel of this unit is set to COUNTER, the value determined by calculation based on the time code is displayed. The value is a simple approximation. Therefore, if you intend to use this unit as a player in the editing system, set the COUNTER SELECT selector to TC and also set the edit mode (EDIT REFERENCE) of the editing controller to time code (TC).
Settings on editing controller
When connecting an editing controller, make the following settings, according to the model used.
Set the VCR device constants as follows:
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |
80 31 00 96 05 05 0A 8A 0A | 08 | FE 00 | 80 | 5A FF |
Set the VCR device constants as follows:
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |
81 31 00 7D 05 05 0A 8A 0A | 08 | FE 00 | 80 | 5A FF |
Set the VCR device constants as follows:
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |
80 31 00 96 05 05 0A 8A 0A | 08 | FE 00 | 80 | 5A FF |
Set the VCR device constants as follows:
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |
81 31 00 7D 05 05 0A 8A 0A | 08 | FE 00 | 80 | 5A FF | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Set the DIP switches as follows:
Left switch
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
OFF | – | – | OFF | – | – | – | – |
Right switch
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
OFF | – | OFF | ON | OFF | OFF | ON | ON |
|
|
|
|
|
|
|
|
Right switch
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
ON | – | OFF | ON | OFF | OFF | ON | ON |
|
|
|
|
|
|
|
|
If the edit timing is out of adjustment, change the setting of items 0 to 2 of the right switch.