General Information | 1 |
|
|
1.2Modle code
|
|
|
| standard |
|
|
|
|
|
|
|
|
| optional |
|
|
| special | |||||
marking |
| a |
| b |
| c |
|
| d |
| e |
|
| f |
| g1 |
| g2 |
| h |
|
| i |
type: | 637f/ | X |
| D6R |
| XX |
| .S5 |
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
marking |
|
|
|
|
|
|
|
| description |
|
|
|
|
|
|
|
| ||||||
| XXXX/ | = 637f ≅ SSD |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
a | K | = |
|
|
|
|
|
|
|
|
|
| |||||||||||
| 0 | = | design |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
b | D6R | = | Digital 6U drive |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
c |
|
| Rated current: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 02 | = | 2 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 04 | = | 4 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 06 | = | 6 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 10 | = | 10 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 16 | = | 16 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 22 | = | 22 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 30 | = | 30 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
d | .S5 | = | Digital servo drive | 5th generation |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
e |
|
| Intermediate circuit rated voltage: |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
| = | 325V (230V AC) | 16..30A only as rack system possible |
|
|
|
|
|
|
| |||||||||||||
| = | 650V (460V AC) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
f | = | With |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| = | Without |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
g1 |
|
| additional option modules on the drive for communication via COM2 |
|
|
|
| ||||||||||||||||
| = | None option |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| = | RS 232 interface |
|
|
|
|
|
|
|
|
|
|
| ≅ slot A (B) |
| ||||||||
| = | RS 422 interface |
|
|
|
|
|
|
|
|
|
|
| ≅ slot A (B) |
| ||||||||
| = | RS 485 interface |
|
|
|
|
|
|
|
|
|
|
| ≅ slot A (B) |
| ||||||||
| = | CAN – Bus |
|
|
|
|
|
|
|
|
|
|
|
| ≅ slot A (B) |
| |||||||
| = | 2 x CAN (without I/O’s) |
|
|
|
|
|
|
|
|
| ≅ slot B (A) / [C*] |
| ||||||||||
| = | 2 x CAN + 4 outputs and 4 inputs |
|
|
|
|
|
|
| ≅ slot B (A) / [C*] |
| ||||||||||||
| = | CAN - Bus / DeviceNet |
|
|
|
|
|
|
|
|
| ≅ slot B (A) |
| ||||||||||
| = | SUCOnet K |
|
|
|
|
|
|
|
|
|
|
|
| ≅ slot B (A) |
| |||||||
| = | Profibus DP |
|
|
|
|
|
|
|
|
|
|
|
| ≅ slot B (A) |
| |||||||
| = | Interbus S |
|
|
| (Attention: changed front plate) |
| ≅ slot B (A) |
| ||||||||||||||
| = | I/O interface (5 inputs, 2 outputs) |
|
|
|
|
|
|
| ≅ slot B | (A) |
| |||||||||||
g2 |
|
| additional option modules on the drive via X200 (Attention: changed front plate) | ||||||||||||||||||||
| = | No Options |
|
|
|
|
|
|
|
|
|
|
|
| ≅ slot C |
|
|
|
| ||||
| = | I/O interface (14 inputs, 10 outputs) |
|
|
|
|
|
|
|
| |||||||||||||
| = | Safety – Board Module |
|
|
|
|
|
|
|
|
| ≅ slot C |
|
|
|
| |||||||
h |
|
| X300 – Function module |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| = | Standard X30 Resolver module 2nd version |
|
|
|
| ≅ slot D |
|
|
|
| ||||||||||||
| = | HIPERFACE module 2nd version |
|
|
|
|
|
|
| ≅ slot D |
|
|
|
| |||||||||
| = | Sinus / Cosinus - module 2nd version |
|
|
|
| ≅ slot D |
|
|
|
| ||||||||||||
i |
|
| Entry only at use |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| = | Special - resistance - setting |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| = |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| = | Protection moisture condensation |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| = Protection moisture condensation + |
| |||||||||||||||||||||
| = Jumper 209 / 2 - 3 open , by SBT - Option Thermo - Contact X30 (PTC / NTC) |
| |||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| at assignment [C] Interface you can used 1 x CAN * |
|
Typical Example
A typical example of an order of a
| Type: | a | b | c | d | e | f | g1 | g2 | h | i |
| 637f/ | KD6R | 02 | .S5 | - | ||||||
|
|
________________________________________________________________________________________________________________________________________________________________________________________________________________________
Product Manaul Type: 637f | 13 |