11

General Technical Data

 

 

 

11.6 Digitale communication

 

 

 

 

RS232 - service interface

 

COM1

 

 

 

19200 baud, 8 databits, 1 startbit, 1 stopbit,

 

 

 

parity: even

 

Optional

 

 

 

RS232 / RS422 / RS 485

 

COM2

 

on SUB D – socket

 

 

 

CAN1, Profibus DP, SUCOnet K

 

 

on SUB D – socket

 

 

 

Interbus S on SUB D – socket (OUT)

 

 

Interbus S (Remote IN)

 

additional on SUB D – socket

 

CAN2

 

 

 

 

 

 

 

11.7 Resolver evaluation/transmitter principle

General:

The specified data refer to the combination of the standard resolver interface with Function-Module X300_RD2; operated with the SSD Drives resolver R 21-T05, R15-T05

carrier frequency

ft = 4,75 kHz

ripple of the speed actual value signal

2% 1)

 

max. position resolution for one revolution

65536 /

16 bit

absolute position accuracy

+/- 0,7 °

1)

relative position accuracy

+/- 0,08 °

1)

1)Data under check, Reality: Quality improved

11.8 Controllersystem

system run-up time after switching on

max. 6 sec.

the control voltage

 

data memory / organization

Flash Eprom 256 KB

 

RAM 64 KB;

 

EEPROM 96 kByte

________________________________________________________________________________________________________________________________________________________________________________________________________________________

74

Product Manual Type: 637f

07-02-10-01-E-V0505.doc