11 | General Technical Data | ||
|
|
| |
11.6 Digitale communication | |||
|
|
|
|
RS232 - service interface |
| COM1 |
|
|
| 19200 baud, 8 databits, 1 startbit, 1 stopbit, |
|
|
| parity: even |
|
Optional |
|
|
|
RS232 / RS422 / RS 485 |
| COM2 |
|
on SUB D – socket |
|
|
|
CAN1, Profibus DP, SUCOnet K |
|
| |
on SUB D – socket |
|
|
|
Interbus S on SUB D – socket (OUT) |
|
| |
Interbus S (Remote IN) |
| additional on SUB D – socket |
|
CAN2 |
|
|
|
|
|
|
|
11.7 Resolver evaluation/transmitter principle
General:
The specified data refer to the combination of the standard resolver interface with
carrier frequency | ft = 4,75 kHz | |
ripple of the speed actual value signal | 2% 1) |
|
max. position resolution for one revolution | 65536 / | 16 bit |
absolute position accuracy | +/- 0,7 ° | 1) |
relative position accuracy | +/- 0,08 ° | 1) |
1)Data under check, Reality: Quality improved
11.8 Controllersystem
system | max. 6 sec. |
the control voltage |
|
data memory / organization | Flash Eprom 256 KB |
| RAM 64 KB; |
| EEPROM 96 kByte |
________________________________________________________________________________________________________________________________________________________________________________________________________________________
74 | Product Manual Type: 637f |