2

Connector Assignments and Functions

 

 

Multi-function X40

2.5.5SSI Encoder Interface

EASYRIDERWindows - Software X40 Mode = SSI_13 bit Singleturn EASYRIDERWindows - Software X40 Mode = SSI _14 bit Singleturn

EASYRIDERWindows - Software X40 Mode = SSI_25 bit Multiturn

(13 bit Single- / 12 bit Multiturn)

EASYRIDERWindows - Software X40 Mode = SSI_26 bit Multiturn

(14 bit Single- / 12 bit Multiturn)

Inr. I/O X40

 

PIN

 

Function

 

 

Designation

 

 

X40

 

 

 

 

 

 

 

 

1

 

Serial data from SSI encoder,

 

/DATA

 

GRAY code up to 26 bit inverted

 

 

 

 

 

 

 

 

 

2

 

Serial data from SSI encoder,

 

DATA

 

GRAY code up to 26 bit

 

 

 

 

 

 

 

 

 

3

 

Shield connector

 

Schirm

4

 

Clock output, inverted

 

/TAKT

 

Standard frequenzy: 179 kHz

 

 

 

 

 

 

 

 

 

5

 

Clock output

 

TAKT

 

Standard frequenzy: 179 kHz

 

 

 

 

 

 

 

 

 

6

 

Reference potential

 

GND

7

 

do not connect

 

 

 

8

 

do not connect

 

 

 

 

 

 

Supply voltage output max. 150 mA

 

+5 VDC

9If other data required:

a)Use of X300 module

b)External supply

TAKT and /TAKT twisted pair DATA and /DATA twisted pair

Cable screened, screen grounded at both sides, max. cable length: 200m

Note:

For further information about SSI (Synchronous Serial Interface), please refer to the documentations of appropriate suppliers. (e.g.: Comp. Sick or Hengstler)