9 | Diagnosis and |
|
|
9.3Trouble shooting
The following list refers to faults which can occur during operation.
Display:
Error |
|
| Explanation and remedy |
|
no motor run despite current flow |
| motor mechanically blocked? | 1) | |
|
|
| motor brake released? |
|
motor runs unevently |
|
| check setpoint wiring |
|
|
|
| check grounding and shielding |
|
|
|
| too high |
|
|
|
| reduce value |
|
|
|
| (with EASYRIDER→ setting/speed control) |
|
|
|
| too small |
|
|
|
| reduce value |
|
|
|
| (with EASYRIDER→ setting/speed control) |
|
no reaction of setpoint progression, despite | Limit switch functions |
| ||
torque in standstill |
|
| effective (BIAS) |
|
no current flow; |
|
| motor cables interrupted? |
|
no torque despite activating the regulator | Is input "I extern" (X10.19) activated |
| ||
correctly |
|
| (config. menu) and not notched up? |
|
|
|
| limit switch - input |
|
|
|
| activated and not notched up? |
|
Interference symptoms with power |
| Ground loops in setpoint or actual value wiring? |
| |
frequency |
|
| Shieldings laid on both sides? |
|
|
|
| Signal cables near high voltage cables? |
|
Motor takes up preferred positions after | Position encoder or motor cables with reversed | 1) | ||
activation |
|
| poles? |
|
|
|
| Resolver or Feedback- encoder incorrectly |
|
|
|
| adjusted? |
|
|
|
| Number of motor poles wrong matching? (config. |
|
|
|
| menu) |
|
Motor runs up immediately after activation | Motor cables or feedback- cables reversed? | 1) | ||
although there is no setpoint |
| Encoder incorrectly adjusted? |
| |
|
|
| (e.g. Resolver) |
|
Motor reaches in idling cycle very different |
| |||
speed when running to the right or to the left | (e.g. Resolver) |
| ||
1) Display | or | mostly short after activating; before warning |
|
________________________________________________________________________________________________________________________________________________________________________________________________________________________
70 | Product Manual Type: 637f |