7

Setting and Programming

 

 

7.1Jumper

All jumpers are set to a standard position in production !

Layout of the Jumpers see: Chapter 1.2.3

JP100,

 

bridged pad...

 

2 and 3

READY contact with reference to

(standard)

common output supply voltage on

 

X10.21

1 and 3

READY contact can be wired freely

 

 

JP101,

 

bridged pad...

 

2 and 3

Analog input X10.19 without internal

(standard)

Pull-up.

1 and 3

Analog input X10.19 with internal Pull-

 

up to +12 V (FRR compatible)

 

 

JP102,

 

bridged pad...

 

2 and 3

X10.23 = active ok. output

(standard)

 

1 and 3

X10.23 = GND internal

 

(FRR compatible)

 

 

JP1, JP2

adjust identically !

bridged pad...

 

2 and 3

X10.15 = high-active

(standard)

 

1 and 3

X10.15 = low-active

 

 

JP3, JP4

adjust identically !

bridged pad...

 

2 and 3

X10.14 = high-active

(standard)

 

1 and 3

X10.14 = low-active

 

 

JP2.8, JP2.3

 

JP2.7, JP2.2

 

open

Default, RP CAN, RP DEV, RP PDP

 

RP 2CA, RP 2C8

close

RP 232, RP 422, RP 485,

 

RP IBS, RP EA5, RP SUC

 

 

JP209 2-3

 

JP209 1-3

 

close

Default RP SBT

Further connecting configuration see:

Product Manualo 07-02-10-02-E-Vxxxx RP_SBT

7.2Digital communication

see: Chapter 13

________________________________________________________________________________________________________________________________________________________________________________________________________________________

60

Product Manual Type: 637f

07-02-10-01-E-V0505.doc